Sentinel 9
SENTINEL

9

Superior Power Systems has decided to apply it's more than 20 years of industrial generator manufacturing experience to the home stand-by generator market. The result is a product unprecedented in quality, appearance and function.

 

HOME STAND-BY GENERATOR

Superior Power System Generators and Automatic Transfer Switches are designed to protect against short and long term power failures. The transfer switch senses and verifies the loss of utility power. The switch waits approximately 3 seconds to insure the failure is bona fide and the generator is necessary. The switch then starts the generator and transfers the load. Your home is now being powered by a state of the art, safe, and reliable power system. The generator will continue to run your basic household needs until the normal utility power is restored. The switch will track the return of Utility power for a period of approximately 5 minutes to insure stability and only then will it transfer your home back to normal power. The generator is then shut down and will continue to stand-by for the next power failure. The transfer switch will start and run the generator with no load for a period of approximately 15 minutes each week. This process monitors your generator's ability to run correctly, exercise routinely and serve you when needed. Proper maintenance is, of course, required.

DOESN'T YOUR HOME DESERVE A SUPERIOR SOLUTION TO POWER LOSSES?

Price does not include battery, delivery, or installation.

SPECIFICATIONS
MODEL FUEL VOLTAGE PHASE RATED
KW
²
RATED
KVA
AMPERAGE
@rated KW
P.F. LINE
BREAKER
SENTINEL 9 L.P. 120/240 1 9 9 37.5 1.0 35
Natural Gas 120/240 1 8 8 33.3 1.0 30

¹ Line breakers are optional and the recommended sizes are established to protect the generator. They are not sized for downstream loads.
² Continuous Standby Rating: The unit will operate, when fueled properly, at this rating, for the duration of normal utility power interruptions.

GAS ENGINE
Engine Data
Manufacturer: Briggs & Stratton
Model: VANGUARD 18
Cycle: 4
Displacement: 34.75 cu.in.
Cylinder Arrangement: vee 2
Bore: 2.83"
Stroke: 2.75"
Compression Ratio: n/a*
Piston Speed: 1650 fpm
Rated Speed: 3600 fpm
HP at Rated RPM: 18 bhp

 

Engine Support Data
Lube Oil Capacity: 56 fl.oz.
Oil Filter (quantity/type): 1 spin-on
Total Inlet Air Required: n/a*
Fuel System: natural gas
Fuel Supply Line min. I.D.: 1"
Secondary Regulator: 1"
Solenoid Valve: 1"
Exhaust Outlet Size: 7/8"
Exhaust Temperature at Rated Output: 1380º F
Governor: mechanical
Battery Charging System Ground (polarity/volts): 12V negative
Ampere Rating: 16
Starter Motor Rating: 12V w/ solenoid

 

Fuel Consumption (typical)
LOAD Natural Gas LP Gas
100% ft.³/hr.: 168 82 or 2.5 gal.
75% ft.³/hr.: 129 64
50% ft.³/hr.: 107 50 or 1.5 gal.
25% ft.³/hr.: 86 39

 

Battery Recommendations
BCI Group Size U1 with minimum 165 cranking amps (not included) n/a* information not available at time of printing

 

WEIGHTS & DIMENSIONS:
Approximate net weight, dry: 275 lbs. &
Overall size: 48 L x 34 W x 30.5 H
(WITH ENCLOSURE & SKID)

STANDARD ACCESSORIES

Fuel System
Flexible Fuel Line

Exhaust System
Lo-Tone silencer
Heat deflector

Cooling System
Forced air cooled directional discharge system

Generator Electrical
Thermal magnetic line circuit breaker, UL listed
see recommendations above

Additional Accessories
1 yr. warranty

Control Features
Test(on)-Off-Auto switch
Low oil pressure cut-out
Cranking limiter
Fused controller circuit
Operator's manual

 

GENERATOR

Generator Data
Type: Brushless, 2 pole, rotating field, drip proof construction.
Stator: Insulation NEMA Class F.
Rotor: Insulation NEMA Class H. Windings are tropicalized to insure performance.
Bearings: Pre-lubricated and rated for a period of 15,000 hours before servicing.
Ventilation: Axial type with air inlet from opposite end. Self-ventilated, low noise air delivery.
Exciter: Brushless, D.C.
Voltage Regulator: Regulation ±5%.
Output: Single phase only.

Generator Performance
One-step Load Acceptance: 100% of nameplate KW rating.
Voltage Regulation: Steady state no load to full load, ±5%
Voltage Recovery: After acceptance of nameplate rating in one step recovery is less then 1 sec.
Standards: Designed and built to meet the following standards: CEI 2-3, VDE 0530, NF C51-100-111 and 112, BS4999-5000.

 

STANDARD AUTOMATIC TRANSFER SWITCH
Includes 100A, 120 / 240 volt, 2 Pole, 1fswitch
Timers include: TDES time delay engine start, adjustable
TDEN time delay emergency to normal, adjustable
7 day programmable exerciser
Battery charger w/ pilot light
Pilot lights for Normal and Emergency positions
Pilot light for normal power available
Test switch
Mechanically and electrically interlocked
NEMA 1 Enclosure
Dimensions: 20.5"W x 18.5"H x 9.0"D
Weight: 47 lbs. typical

 

The information contained herein is general in nature and is not intended for specific application purposes. Superior Power Systems reserves the right to make improvements and changes in specifications shown herein without obligation. Please consult factory for current data.
This equipment is designed for outdoor installation only and should not, under any circumstances, be mounted within a building or structure !!

Superior Power Systems
7 Franklin McKay Rd
Attleboro, MA 02703
508-226-3410
508-222-6378 FAX

email: info@superiorpowersys.com